ACT 5e prox Operating and Installation Manual Rev 1.0
Set Door Relay Time: Enter Programming Mode, then Press:
Step Keypad Entry Operation
1 2 Set Door Relay Time – (default 5 seconds, maximum 255 seconds)
2 0 Buzzer sounds indicating timing… wait required period
3 Press End setting Door Relay Timer
Set Toggle Mode: Enter Programming Mode, then Press:
Step Keypad Entry Operation Example: Set user 12 to toggle
relay when access granted
1 1 Set Toggle Mode 1 Set Toggle Mode
2 00-49 Enter 2 digit User Number 00-49 12 User 12
3 0 or 1 0 = Relay Toggle, 1 = Relay Timed 0 Relay Toggle
Deleting User’s Card: Enter Programming Mode, then Press:
Step Keypad Entry Operation Example: Set user 12 to toggle relay
when access granted
1 6 Delete User’s Card 6 Delete cards
2 00-49 First user to delete 10 User 10
3 00-49 Last user to delete 10 User 10
Deleting Card Number: Enter Programming Mode, then Press:
Step Keypad Entry Operation
1 7 Delete card number
2 10 digit card
number
10-digit Card number with leading zeroes.
E.g. Card 54321, enter 0000054321
Check if User has no PIN Assigned: Enter Programming Mode, then Press:
Step Keypad Entry Operation
1 80 Check if user has no PIN already assigned
2 00-49 User 0-49
Keypad will flash the green led and sound high-pitched tone if the user has NO PIN code
assigned. It will flash red and sound low-pitched tone, if the user has a PIN code.
Check if User has no Card Assigned
Step Keypad Entry Operation
1 81 Check for user with no card assigned
2 00-49 User 0-49
Keypad will flash the green led and sound high-pitched tone if the user has NO card
assigned. It will flash red and sound low-pitched tone, if the user has a card.
Programming ACT 5e prox Options: Enter Programming Mode, then Press:
Step Keypad Entry Operation
1 30, 31,32,40 or 41 2 digit option number
2 0 or 1 0=Off, 1= On
- 6 -