HandKey II Manual
5
Size: 8.85 inches wide by 11.65 inches high by 8.55 inches deep (22.3
cm)
22.3 cm wide by 29.6 cm high by 21.7 cm deep
Power: 12 to 24 VDC or 12 to 24 VAC 50-60 Hz, 7 watts
Weight: 6 lbs (2.7 kg)
Wiring: 2 twisted-pair, shielded, AWG 22 or larger (such as Belden
82732)
Temperature: -10C to +60C – non-operating/storage (14F to 140F)
0C to 45C – operating (32F to 113F)
Relative Humidity
Non-Condensing:
5% to 85% – non-operating/storage
20% to 80% – operating
Verification Time: 1 second or less
Memory Retention: 5 years using a standard internal lithium battery
Transaction Buffer: 5120 transactions
ID Number Length: 1 to 10 digits
Baud Rate: 300 to 28.8 K bps
Communications: RS-232, RS-422, RS-485 2-wire, optional Ethernet, optional
Modem
User Capacity: 512 users expandable to 259,072
Card Reader Input: Proximity, Wiegand, Magnetic Stripe, Bar Code
(5 VDC provided by HandReader)
Card Reader Output: Wiegand, Magnetic Stripe, Bar Code
Duress Code: 1 leading digit, user definable
Door Controls: Request to Exit input, Door Switch input, Lock output (open
collector, 5 VDC present, sinks to ground, 100 mA max)
Alarm Monitoring: Tamper, Door Forced, Duress
Event Monitoring: There is a variety of monitoring options including events such as:
Invalid ID, Time Zone Violation, ID Refused, Try Again,
Power Failure
Time Zones: 62 total – 2 fixed, 60 programmable
Auxiliary Outputs: 3 user definable
(open collector, 5 VDC present, sinks to ground, 100 mA max)
Auxiliary Inputs: Auxiliary Input 1 and 2 (open collector, 5 VDC present, sinks to
ground, 100 mA max)
Specifications